Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
JCO Clin Cancer Inform ; 6: e2200023, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36332157

RESUMEN

PURPOSE: Variability in computed tomography images intrinsic to individual scanners limits the application of radiomics in clinical and research settings. The development of reproducible and generalizable radiomics-based models to assess lesions requires harmonization of data. The purpose of this study was to develop, test, and analyze the efficacy of a radiomics data harmonization model. MATERIALS AND METHODS: Radiomic features from biopsy-proven untreated hepatic metastasis (N = 380) acquired from 167 unique patients with pancreatic, colon, and breast cancers were analyzed. Radiomic features from volume-match 551 samples of normal liver tissue and 188 hepatic cysts were included as references. A novel linear mixed effect model was used to identify effects associated with lesion size, tissue type, and scanner model. Six separate machine learning models were then used to test the effectiveness of radiomic feature harmonization using multivariate analysis. RESULTS: Proposed model identifies and removes scanner-associated effects while preserving cancer-specific functional dependence of radiomic features on the tumor size. Data harmonization improves the performance of classification models by reducing the scanner-associated variability. For example, the multiclass logistic regression model, LogitBoost, demonstrated the improvement in sensitivity in the range from 15% to 40% for each type of liver metastasis, whereas the overall model accuracy and the kappa coefficient increased by 5% and 8% accordingly. CONCLUSION: The model removed scanner-associated effects while preserving cancer-specific functional dependence of radiomic features.


Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada por Rayos X , Humanos , Femenino , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Mama/diagnóstico por imagen , Aprendizaje Automático
2.
Pediatr Res ; 92(6): 1621-1629, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35184137

RESUMEN

BACKGROUND: Benefits from early surgical intervention in preterm infants with intraventricular hemorrhage (IVH) prior to symptomatic ventriculomegaly must be weighed against risks of surgery. We calculated thresholds of common ventriculomegaly indices at a late-intervention institution to predict subsequent symptomatic ventriculomegaly requiring neurosurgery. METHODS: We retrospectively reviewed neuroimaging and neurosurgical outcomes in preterm infants with grade III/IV IVH between 2007 and 2020. Frontal-occipital horn ratio (FOHR), frontal-temporal horn ratio (FTHR), anterior horn width (AHW), and ventricular index (VI) were measured. Area under the receiver operating curve (AUC) for predicting intervention (initiated after progressive symptomatic ventriculomegaly) was calculated for diagnostic scan, scans during weeks 1-4, and maximum measurement prior to intervention. Threshold values that optimized sensitivity and specificity were derived. RESULTS: A total of 1254 scans in 132 patients were measured. In all, 37 patients had a neurosurgical intervention. All indices differed between those with and without intervention from the first diagnostic scan (p < 0.001). AUC of maximum measurement was 97.1% (95% CI 94.6-99.7) for FOHR, 97.7% (95% CI 95.6-99.8) for FTHR, 96.6% (95% CI 93.9-99.4) for AHW, and 96.8% (95% CI 94.0-99.5) for VI. Calculated thresholds were FOHR 0.66, FTHR 0.62, AHW 15.5 mm, and VI 8.4 mm > p97 (sensitivities >86.8%, specificities >90.1%). CONCLUSION: Ventriculomegaly indices were greater for patients who developed progressive persistent ventriculomegaly from the first diagnostic scan and predicted neurosurgical intervention. IMPACT: We derived thresholds of common ventriculomegaly indices (ventricular index, anterior frontal horn width, fronto-occipital horn and fronto-temporal horn index) to best predict the development of progressive symptomatic post-hemorrhage hydrocephalus in preterm infants with intraventricular hemorrhage. While current thresholds were established by a priori expert consensus, we report the first data-driven derivation of ventriculomegaly thresholds across all indices for the prediction of symptomatic hydrocephalus. Data-derived thresholds will more precisely weigh the risks and benefits of early intervention.


Asunto(s)
Enfermedades Fetales , Hidrocefalia , Enfermedades del Prematuro , Lactante , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro , Estudios Retrospectivos , Dilatación , Hidrocefalia/diagnóstico por imagen , Hemorragia Cerebral/complicaciones , Hemorragia Cerebral/diagnóstico por imagen , Ventrículos Cerebrales
3.
J Magn Reson Imaging ; 56(2): 440-449, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34953154

RESUMEN

BACKGROUND: Gadobutrol (GB) and gadoterate meglumine (GM) are contrast agents used for contrast-enhanced magnetic resonance angiography (CEMRA). Supraaortic vasculature (SAV) CEMRAs are used to evaluate stroke risk and neurologic symptoms. There is a need to compare the SAV CEMRA image quality obtained with GB and GM. PURPOSE: To intra-individually compare MRA images obtained with equimolar GB and GM at 1.5 T in the SAV. STUDY TYPE: Prospective, crossover. POPULATION: Twenty-eight subjects (54 ± 13 years; 17 female). FIELD STRENGTH/SEQUENCE: 1.5 T; three-dimensional (3D) gradient recalled echo. ASSESSMENT: Quantitative image quality was measured by normalized signal intensity (SIn ) [SIn  = SI blood/SD blood] and contrast ratio (CR) [CR = SI blood/SI muscle], determined by an observer (JWC) with 1 year of vascular imaging experience. Three radiologists (AS, PA, and MU) with (5, 5, and 6 years of) vascular imaging experience evaluated image quality by Likert-scale ratings (of image impression, wall conspicuity, and artifact absence). STATISTICAL TESTS: SIn and CR were compared with paired t-tests or Wilcoxon signed-rank tests and Bland-Altman plots. Qualitative ratings were compared with Wilcoxon signed-rank test. RESULTS: No significant difference in SIn was found between GB and GM. CRs with GB were significantly higher than GM at the right common carotid (6.9 ± 2.5 vs. 4.8 ± 1), left internal carotid (7.3 ± 2 vs. 4.4 ± 1.2), right internal carotid (7.7 ± 2.2 vs. 5 ± 1.1), and left vertebral (6.6 ± 2.2 vs. 4.5 ± 1.1) arteries. Bland-Altman plots showed relatively greater differences between GB and GM at higher CRs and SIn s. GM showed significantly higher artifact than GB (3.56 ± 0.52 vs. 3.36 ± 0.46) and significantly lower overall image quality (10.73 ± 1.45 vs. 11.26 ± 1.58) at the left vertebral artery. DATA CONCLUSION: At 1.5 T and equimolar demonstration, GB (0.1 mL/kg, i.e., 0.1 mmol/kg) showed higher CRs in the SAV compared to GM (0.2 mL/kg, i.e., 0.1 mmol/kg) at most vessels. Subjective image quality was not significantly different between the two agents for most vessels. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Angiografía por Resonancia Magnética , Compuestos Organometálicos , Medios de Contraste , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Meglumina , Estudios Prospectivos , Reproducibilidad de los Resultados
4.
Childs Nerv Syst ; 38(2): 455-460, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34115176

RESUMEN

Gorham Stout disease (GSD) is a rare disease characterized by the proliferation of endothelial lined vessels and replacement of bone by fibrous tissue. The main imaging features are progressive osteolysis and cortical resorption. Temporal bone involvement is rare but presents as a destructive bone lesion that may be misinterpreted as more common lytic processes in the pediatric population, such as infection or Langerhans cell histiocytosis. GSD of the temporal bone is associated with cerebrospinal fluid (CSF) leaks, may present with otorrhea, and can mimic other causes of ear drainage. Here, we report the clinical course, imaging features, and outcomes of a 3-year-old girl with GSD of the temporal bone presenting with CSF leak initially attributed to infection.


Asunto(s)
Osteólisis Esencial , Pérdida de Líquido Cefalorraquídeo/diagnóstico por imagen , Pérdida de Líquido Cefalorraquídeo/etiología , Pérdida de Líquido Cefalorraquídeo/cirugía , Niño , Preescolar , Femenino , Humanos , Osteólisis Esencial/complicaciones , Osteólisis Esencial/diagnóstico por imagen , Osteólisis Esencial/patología , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/patología
5.
Explor Res Hypothesis Med ; 6(3): 90-98, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34589655

RESUMEN

BACKGROUND AND OBJECTIVES: Renal transplant patients often require periodic imaging to evaluate the transplant vessel anastomosis for potential vascular complications. The use of non-contrast enhanced magnetic resonance angiography (NCE-MRA) techniques is encouraged in these patients because they are at increased risk of nephrogenic systemic fibrosis (NSF) due to their renal insufficiency. This study aimed to evaluate the performance of two NCE-MRA techniques (three-dimensional [3D] balanced steady-state free precession [bSSFP] with inversion recovery and quiescent-interval slice-selective [QISS]) for the evaluation of renal allograft vasculature in patients with clinical suspicion, or Doppler ultrasound, or both of arterial anastomotic stenosis. METHODS: A total of 43 patients were included in this retrospective study. Two radiologists independently scored the images from 3D bSSFP and QISS MRA sequences for image quality and confidence in anastomosis interpretation, and the degree of stenosis at the arterial anastomosis. Correlations with digital subtraction angiography (DSA) were carried out when available. In addition, inter-rater agreement was calculated. RESULTS: In total, 43 patients underwent QISS and 3D bSSFP MRA. For QISS, all cases were adequate for evaluation. For 3D SSFP, 86% of cases were adequate for evaluation. There was a good-to-excellent inter-rater agreement for all scores and an excellent correlation between NCE-MRA and DSA results when available (12 patients). CONCLUSIONS: QISS and 3D SSFP showed good inter-rater agreement for image quality and stenosis grade, with more cases being of adequate image quality that used QISS. Further study is required; however, NCE-MRA shows potential as a risk-free alternative to CTA and contrast-enhanced MRA (CE-MRA) for the evaluation of arterial anastomoses in renal transplant patients.

6.
MAGMA ; 34(5): 649-658, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33963454

RESUMEN

OBJECTIVE: To evaluate the potential clinical benefit of the superior spatial resolution of 3D prototype thin-slab stack-of-stars (tsSOS) quiescent-interval slice-selective (QISS) MRA over standard 2D-QISS MRA for the detection peripheral artery disease (PAD), using computed tomography angiography (CTA) as reference. MATERIALS AND METHODS: Twenty-three patients (70 ± 8 years, 18 men) with PAD who had previously undergone run-off CTA were prospectively enrolled. Patients underwent non-contrast MRA using 2D-QISS and tsSOS-QISS at 1.5 T. Eighteen arterial segments were evaluated for subjective and objective image quality (normalized signal-to-noise, nSNR), vessel sharpness, and area under the curve (AUC) for > 50% stenosis detection. RESULTS: Overall subjective image quality ratings for the entire run-off were not different between tsSOS-QISS and 2D-QISS (3 [3; 4] vs 4 [3; 4], respectively; P = 0.813). Sharpness of primary branch vessels demonstrated improved image quality using tsSOS-QISS compared with 2D-QISS (4 [3; 4] vs 3 [2; 3], P = 0.008). Objective image quality measures were not different between 2D-QISS and tsSOS-QISS (nSNR 5.0 ± 1.9 vs 4.2 ± 1.8; P = 0.132). AUCs for significant stenosis detection by tsSOS-QISS and 2D-QISS were 0.877 and 0.856, respectively (P = 0.336). DISCUSSION: The prototype 3D tsSOS-QISS technique provides similar accuracy in patients with PAD to a standard commercially available 2D-QISS technique, indicating that the use of relatively thick slices does not limit the diagnostic performance of 2D-QISS. However, subjective image quality for branch vessel depiction is improved using the 3D approach.


Asunto(s)
Enfermedad Arterial Periférica , Constricción Patológica , Medios de Contraste , Humanos , Angiografía por Resonancia Magnética , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Reproducibilidad de los Resultados
7.
Int J Cardiovasc Imaging ; 37(2): 651-661, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32968888

RESUMEN

To evaluate k-t accelerated 3D cine b-SSFP (balanced steady state free precession) as magnetic resonance imaging (MRI) technique for aortic annular area measurement in transcatheter aortic valve replacement (TAVR) planning compared to computed tomography angiography (CTA) and other non-contrast MRI sequences with reduced imaging time and without contrast administration. 6 volunteers and 7 TAVR candidates were prospectively enrolled. The volunteers underwent an MRI while TAVR candidates underwent an MRI and CTA. The following non-contrast MRI sequences were obtained at the level of the aortic root: 2D cine b-SSFP [GRAPPA (GeneRalized Autocalibrating Partially Parallel Acquisitions), R = 2], 3D cine b-SSFP [GRAPPA R = 2], navigator triggered 3D b-SSFP MRA [GRAPPA, R = 2] and k-t accelerated 3D cine b-SSFP [PEAK GRAPPA, R = 5]. Qualitative analysis and aortic annular area measurements in systole and diastole were obtained. k-t accelerated 3D cine b-SSFP provided image quality that is acceptable for confident diagnosis with very good interrater agreement. There was no statistically significant difference in aortic annular measurements between k-t accelerated 3D cine b-SSFP and CTA or other MRI sequences (p > 0.05). Bland-Altman analysis showed no systemic difference of annular area measurements between k-t accelerated 3D cine b-SSFP and each of the other techniques. There was excellent inter-rater agreement on aortic annular area measurements during systolic (ICC = 0.976, p < 0.001) and diastolic (ICC = 0.971, p < 0.001) phases using k-t accelerated 3D cine b-SSFP. K-t accelerated 3D cine b-SSFP is a promising alternative for the assessment of annular sizing in pre-TAVR evaluation while offering a reasonable combination of imaging parameters during one breath-hold.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Imagen por Resonancia Cinemagnética , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estudios de Casos y Controles , Toma de Decisiones Clínicas , Estudios de Factibilidad , Prótesis Valvulares Cardíacas , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Adulto Joven
8.
Acta Radiol ; 62(5): 667-672, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32567320

RESUMEN

BACKGROUND: The diagnosis of congenital uterine anomalies and the differentiation between different subtypes is based on various sets of measurements that are difficult to implement during daily workflow. PURPOSE: To describe the shape and range of measurements of the normal uterus at the fundus in women of reproductive age. MATERIAL AND METHODS: This retrospective study was conducted on 200 pelvic magnetic resonance imaging (MRI) examinations of female patients of reproductive age with normal uteri divided into three age groups (15-24 years, 25-34 years, 35-45 years). The shape of the endometrium and serosa were documented. The thickness from the external to the internal fundic contour and the intercornual distance were measured. RESULTS: The shape of endometrium is most commonly concave or flat but is not uncommonly convex. The shape of the serosa is convex in most cases but can be flat or concave. There is a progressive increase in thickness at the fundus with increased age with mean values of 10.8, 12.3, and 13.6 mm and ranges of 5.6-15.8 mm, 7-18.7 mm, and 7.3-19.8 mm, respectively, in the first, second, and third age groups. There is a progressive increase in intercornual distance with age with mean values of 41.4, 44.5, 47.2 mm and ranges of 30.6-50.7 mm, 31.5-57.3 mm, and 35.2-61 mm, respectively, in the first, second, and third age groups. CONCLUSION: Our study reports the range of normality in shape and measurement of the uterine fundus to aid in the detection of congenital uterine abnormalities.


Asunto(s)
Imagen por Resonancia Magnética , Útero/anatomía & histología , Útero/diagnóstico por imagen , Adolescente , Adulto , Documentación , Femenino , Humanos , Persona de Mediana Edad , Valores de Referencia , Estudios Retrospectivos , Adulto Joven
9.
J Cardiovasc Magn Reson ; 22(1): 78, 2020 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-33256791

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) or contrast-enhanced (CE) cardiovascular magnetic resonance angiography (CMRA) is often obtained in patients with atrial fibrillation undergoing evaluation prior to pulmonary vein (PV) isolation. Drawbacks of CTA include radiation exposure and potential risks from iodinated contrast agent administration. Free-breathing 3D balanced steady-state free precession (bSSFP) Non-contrast CMRA is a potential imaging option, but vascular detail can be suboptimal due to ghost artifacts and blurring that tend to occur with a Cartesian k-space trajectory or, in some cases, inconsistent respiratory gating. We therefore explored the potential utility of both breath-holding and free-breathing non-contrast CMRA, using radial k-space trajectories that are known to be less sensitive to flow and motion artifacts than Cartesian. MAIN BODY: Free-breathing 3D Cartesian and radial stack-of-stars acquisitions were compared in 6 healthy subjects. In addition, 27 patients underwent CTA and non-contrast CMRA for PV mapping. Three radial CMR acquisition strategies were tested: (1) breath-hold (BH) 2D radial bSSFP (BH-2D); (2) breath-hold, multiple thin-slab 3D stack-of-stars bSSFP (BH-SOS); and (3) navigator-gated free-breathing (FB) 3D stack-of-star bSSFP using a spatially non-selective RF excitation (FB-NS-SOS). A non-rigid registration algorithm was used to compensate for variations in breath-hold depth. In healthy subjects, image quality and vessel sharpness using a free-breathing 3D SOS acquisition was significantly better than free-breathing (FB) Cartesian 3D. In patients, diagnostic image quality was obtained using all three radial CMRA techniques, with BH-SOS and FB-NS-SOS outperforming BH-2D. There was overall good correlation for PV maximal diameter between BH-2D and CTA (ICC = 0.87/0.83 for the two readers), excellent correlation between BH-SOS and CTA (ICC = 0.90/0.91), and good to excellent correlation between FB-NS-SOS and CTA (ICC = 0.87/0.94). For PV area, there was overall good correlation between BH-2D and CTA (ICC = 0.79/0.83), good to excellent correlation between BH-SOS and CTA (ICC = 0.88/0.91) and excellent correlation between FB-NS-SOS and CTA (ICC = 0.90/0.95). CNR was significantly higher with BH-SOS (mean = 11.04) by comparison to BH-2D (mean = 6.02; P = 0.007) and FB-NS-SOS (mean = 5.29; P = 0.002). CONCLUSION: Our results suggest that a free-breathing stack-of-stars bSSFP technique is advantageous in providing accurate depiction of PV anatomy and ostial measurements without significant degradation from off-resonance artifacts, and with better image quality than Cartesian 3D. For patients in whom respiratory gating is unsuccessful, a breath-hold thin-slab stack-of-stars technique with retrospective motion correction may be a useful alternative.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Flebografía , Venas Pulmonares/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Fibrilación Atrial/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Estudios de Casos y Controles , Angiografía por Tomografía Computarizada , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Venas Pulmonares/cirugía , Reproducibilidad de los Resultados
10.
Magn Reson Med ; 84(6): 3316-3324, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32521094

RESUMEN

PURPOSE: To report a 3D multi-echo thin-slab stack-of-stars (tsSOS) quiescent-interval slice-selective (QISS) strategy for high-resolution magnetic resonance angiography (MRA) of the entire neck in under seven minutes. METHODS: The neck arteries of eight subjects were imaged at 3 Tesla. Multi-echo 3D tsSOS QISS using a FLASH readout was compared with 3D tsSOS FLASH, 2D QISS, 2D TOF, and 3D TOF. A root-mean-square (RMS) combination of echo time images was tested. Evaluation metrics included arterial signal-to-noise ratio (SNR), arterial-to-muscle contrast-to-noise ratio (CNR), and image quality. RESULTS: 3D multi-echo tsSOS QISS using a RMS combination of echo time images increased SNR and CNR by 60% and 63% with respect to the reconstruction obtained with the shortest echo time. 3D tsSOS QISS showed superior CNR with respect to 3D tsSOS FLASH imaging, and more than 3-fold higher SNR and CNR with respect to 2D radial QISS when normalized for voxel size. 3D tsSOS QISS provided good to excellent image quality that exceeded the image quality of 2D QISS, 2D TOF, and 3D TOF (P < .05). CONCLUSION: Whole-neck high-resolution nonenhanced MRA is feasible using 3D tsSOS QISS, and produced image quality that exceeded those of competing nonenhanced MRA protocols at 3 Tesla.


Asunto(s)
Angiografía por Resonancia Magnética , Cuello , Arterias , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados
11.
J Thorac Imaging ; 35(6): 377-382, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32079906

RESUMEN

PURPOSE: To evaluate image quality and aortic dimension measurement accuracy of high resolution, motion compensated steady-state magnetic resonance angiography (SS-MRA) with a high relaxivity, extracellular fluid gadolinium-based contrast agent compared with standard first-pass contrast enhanced MRA (FP-CEMRA) in patients with thoracic aortic aneurysms. MATERIALS AND METHODS: Sixty-nine patients (mean age, 51.7 y, 25% female) diagnosed with thoracic aortic aneurysms who underwent MRA on a 1.5 T scanner using FP-CEMRA and SS-MRA techniques were retrospectively identified. Quantitative analysis was performed by measuring the aortic diameters at 6 locations within the thoracic aorta for each technique. Two radiologists independently performed the qualitative analysis by assessing the image quality (1 to 5), presence of artifact (1 to 4), signal-to-noise (1 to 4), contrast-to-noise (1 to 4), and wall conspicuity (1 to 4) in the aorta at 4 different locations: the aortic root, the ascending aorta, the aortic arch, and the descending aorta. RESULTS: The aortic dimensions obtained by SS-MRA had a good correlation with FP-CEMRA. Means for the aortic diameters between the FP-CEMRA and the SS-MRA at all 6 locations demonstrated minimal mean differences (0.013 to 0.044 mm).Qualitative assessment of aorta at 4 locations by 2 reviewers demonstrated that SS-MRA had on average superior image quality at the aortic root and ascending aorta for both reviewers (P<0.05) and at the descending aorta for one reader (P<0.05). Otherwise, both techniques were comparable at the ascending aorta. SS-MRA demonstrated less artifact at the aortic root and the ascending aorta (P<0.05). CONCLUSION: Aortic dimension measurements provided by SS-MRA with a high relaxivity, extracellular fluid gadolinium-based contrast agent are comparable to the conventional FP-CEMRA. Furthermore, SS-MRA qualitatively demonstrated comparable to better overall image quality than FP-CEMRA at different aortic locations. Therefore, SS-MRA may provide a comparable alternative, or complementary examination to conventional FP-CEMRA in patients who have difficulty breath holding, or in situations where contrast bolus timing was poor.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Aorta Torácica/diagnóstico por imagen , Medios de Contraste , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
Magn Reson Med ; 84(2): 825-837, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31975432

RESUMEN

PURPOSE: To develop and test the feasibility of a sub-3-minute imaging strategy for non-contrast evaluation of the extracranial carotid arteries using ungated quiescent interval slice-selective (QISS) MRA, combining single-shot radial sampling with deep neural network-based image processing to optimize image quality. METHODS: The extracranial carotid arteries of 12 human subjects were imaged at 3 T using ungated QISS MRA. In 7 healthy volunteers, the effects of radial and Cartesian k-space sampling, single-shot and multishot image acquisition (1.1-3.3 seconds/slice, 141-423 seconds/volume), and deep learning-based image processing were evaluated using segmental image quality scoring, arterial temporal SNR, arterial-to-background contrast and apparent contrast-to-noise ratio, and structural similarity index. Comparison of deep learning-based image processing was made with block matching and 3D filtering denoising. RESULTS: Compared with Cartesian sampling, radial k-space sampling increased arterial temporal SNR 107% (P < .001) and improved image quality during 1-shot imaging (P < .05). The carotid arteries were depicted with similar image quality on the rapid 1-shot and much lengthier 3-shot radial QISS protocols (P = not significant), which was corroborated in patient studies. Deep learning-based image processing outperformed block matching and 3D filtering denoising in terms of structural similarity index (P < .001). Compared with original QISS source images, deep learning image processing provided 24% and 195% increases in arterial-to-background contrast (P < .001) and apparent contrast-to-noise ratio (P < .001), and provided source images that were preferred by radiologists (P < .001). CONCLUSION: Rapid, sub-3-minute evaluation of the extracranial carotid arteries is feasible with ungated single-shot radial QISS, and benefits from the use of deep learning-based image processing to enhance source image quality.


Asunto(s)
Aprendizaje Profundo , Arterias Carótidas/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética
13.
Pediatr Cardiol ; 41(2): 350-360, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31858201

RESUMEN

Aortic root size and cusp fusion pattern have been related to disease outcomes in bicuspid aortic valve (BAV). This study seeks to characterize symmetry of the aortic sinuses in adult and pediatric BAV patients and its relationship to valvulopathy and root aortopathy. Aortic sinus-to-commissure (S-C) lengths were measured on cardiac MRI of adult and pediatric BAV patients with right-and-left coronary (RL) or right-and-non-coronary (RN) leaflet fusion and tricuspid aortic valve (TAV) controls. Coefficient of variance (CoV) of S-C lengths was calculated to quantify sinus asymmetry, or eccentricity. BAV cohort included 149 adults (48 ± 15 years) and 51 children (15 ± 5 years). TAV cohort included 40 adults (60 ± 13 years) and 20 children (15 ± 5 years). In adult and pediatric BAV patients, the non-fused aortic sinus was larger than either fused sinus. In RL fusion, the non-coronary S-C distance was larger than right or left S-C distances in adults (n = 121, p < 0.001) and larger than the right S-C distance in children (n = 41, p = 0.013). Sinus eccentricity (CoV) in BAV patients was higher than in TAV patients (p < 0.001) and did not correlate with age (p = 0.12). CoV trended higher in RL adults with aortic regurgitation (AR) compared to those without AR (p = 0.081), but was lower in RN adults with AR than without AR (p = 0.006). CoV did not correlate to root Z scores (p = 0.06-0.55) or ascending aortic (AAo) Z scores in adults (p = 0.45-0.55) but correlated negatively to AAo Z score in children (p = 0.005-0.03). Most adult and pediatric BAV patients with RL and RN leaflet fusion demonstrate eccentric dominance of the non-fused aortic sinus irrespective of age. The degree of eccentricity varies with valve dysfunction and BAV phenotype but does not relate to the degree of aortic root dilatation, nor does eccentricity correlate with ascending aorta dilatation in adults.


Asunto(s)
Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/patología , Seno Aórtico/patología , Adolescente , Adulto , Aorta/diagnóstico por imagen , Aorta/patología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Enfermedad de la Válvula Aórtica Bicúspide , Niño , Femenino , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Seno Aórtico/diagnóstico por imagen , Adulto Joven
14.
Magn Reson Med ; 81(1): 524-532, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30229565

RESUMEN

PURPOSE: To develop an accelerated, free-breathing, noncontrast, electrocardiograph-triggered, thoracic MR angiography (NC-MRA) pulse sequence capable of achieving high spatial resolution at clinically acceptable scan time and test whether it produces clinically acceptable image quality in patients with suspected aortic disease. METHODS: We modified a "coronary" MRA pulse sequence to use a stack-of-stars k-space sampling pattern and combined it with golden-angle radial sparse parallel (GRASP reconstruction to enable self-navigation of respiratory motion and high data acceleration. The performance of the proposed NC-MRA was evaluated in 13 patients, where clinical standard contrast-enhanced MRA (CE-MRA) was used as control. For visual analysis, two readers graded the conspicuity of vessel lumen, artifacts, and noise level on a 5-point scale (overall score index = sum of three scores). The aortic diameters were measured at seven standardized locations. The mean visual scores, inter-observer variability, and vessel diameters were compared using appropriate statistical tests. RESULTS: The overall mean visual score index (12.1 ± 1.7 for CE-MRA versus 12.1 ± 1.0 for NC-MRA) scores were not significantly different (P > 0.16). The two readers' scores were significantly different for CE-MRA (P = 0.01) but not for NC-MRA (P = 0.21). The mean vessel diameters were not significantly different, except at the proximal aortic arch (P < 0.03). The mean diameters were strongly correlated (R2 ≥ 0.96) and in good agreement (absolute mean difference ≤ 0.01 cm and 95% confidence interval ≤ 0.62 cm). CONCLUSION: This study shows that the proposed NC-MRA produces clinically acceptable image quality in patients at high spatial resolution (1.5 mm × 1.5 mm × 1.5 mm) and clinically acceptable scan time (~6 min).


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Electrocardiografía , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética , Anciano , Aorta/diagnóstico por imagen , Artefactos , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Movimiento (Física) , Variaciones Dependientes del Observador , Respiración
15.
Magn Reson Med ; 81(4): 2632-2643, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30417932

RESUMEN

PURPOSE: To develop an accelerated cardiac perfusion pulse sequence and test whether it is capable of increasing spatial coverage, generating high-quality images, and enabling quantification of myocardial blood flow (MBF). METHODS: We implemented an accelerated first-pass cardiac perfusion pulse sequence by combining radial k-space sampling, compressed sensing (CS), and k-space weighted image contrast (KWIC) filtering. The proposed and clinical standard pulse sequences were evaluated in a randomized order in 13 patients at rest. For visual analysis, 3 readers graded the conspicuity of wall enhancement, artifact, and noise level on a 5-point Likert scale (overall score index = sum of 3 individual scores). Resting MBF was calculated using a Fermi function model with and without KWIC filtering. Mean visual scores and MBF values were compared between sequences using appropriate statistical tests. RESULTS: The proposed pulse sequence produced greater spatial coverage (6-8 slices) with higher spatial resolution (1.6 × 1.6 × 8 mm3 ) and shorter readout duration (78 ms) compared to clinical standard (3-4 slices, 3 × 3 × 8 mm3 , 128 ms, respectively). The overall image score index between accelerated (11.1 ± 1.3) and clinical standard (11.2 ± 1.3) was not significantly different (P = 0.64). Mean resting MBF values with KWIC filtering (0.9-1.2 mL/g/min across different slices) were significantly lower (P < 0.0001) than those without KWIC filtering (3.1-4.3 mL/g/min) and agreed better with values reported in literature. CONCLUSION: An accelerated, first-pass cardiac perfusion pulse sequence with radial k-space sampling, CS, and KWIC filtering is capable of increasing spatial coverage, generating high-quality images, and enabling quantification of MBF.


Asunto(s)
Medios de Contraste/química , Circulación Coronaria , Corazón/diagnóstico por imagen , Miocardio/patología , Adulto , Algoritmos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Método de Montecarlo , Movimiento (Física) , Análisis Multivariante , Perfusión , Estudios Prospectivos , Distribución Aleatoria
16.
J Cardiovasc Magn Reson ; 20(1): 51, 2018 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-30078377

RESUMEN

BACKGROUND: Comparing cardiovascular magnetic resonance (CMR) angiography with computed tomography angiography (CTA), a major deficiency has been its inability to reliably image peripheral vascular calcifications that may impact the choice of interventional strategy and influence patient prognosis. Recently, MRI using a proton density-weighted, in-phase stack of stars (PDIP-SOS) technique has proved capable of detecting these calcifications. The goal of the present study was two-fold: (1) to determine whether magnetic field strength impacts the apparent size and conspicuity of ilio-femoral arterial calcifications; and (2) to determine whether the technique can be accurately applied to image aorto-iliac arterial calcifications. MAIN BODY: Two patient cohorts were studied. For the first cohort, ilio-femoral arterial calcifications were imaged at 1.5 Tesla in 20 patients and at 3 Tesla in 12 patients. For the second cohort, aorto-iliac arterial calcifications were imaged in 10 patients at 3 Tesla and one patient at 1.5 Tesla. Qualitative image analysis as well as quantitative analysis using a semi-automated technique were performed using CTA as the reference standard. Qualitatively, most PDIP-SOS CMR images showed good-to-excellent confidence to detect vascular calcifications, with good-to-excellent inter-reader agreement (κ = 0.67 for ilio-femoral region, P < 0.001; κ = 0.80 for aorto-iliac region, P < 0.01). There was an overall excellent correlation (r = 0.98, P < 0.001) and agreement (intraclass correlation coefficient = 0.97, P < 0.001) between PDIP-SOS CMR and CTA measures of calcification volume in both regions, with no overt difference in performance at 1.5 Tesla vs. 3 Tesla for ilio-femoral calcifications. CMR lesion volumes were slightly lower than those measured for CTA. CONCLUSION: Using PDIP-SOS CMR, aorto-iliac and ilio-femoral calcifications could be simultaneously evaluated at 3 Tesla in less than six minutes with excellent correlation and agreement to CTA. Our results suggest that PDIP-SOS CMR provides a reliable alternative to CT for pre-interventional evaluation of peripheral vascular calcium burden.


Asunto(s)
Aorta/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aortografía/métodos , Arteria Femoral/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Femenino , Humanos , Illinois , Campos Magnéticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...